HPE Best Practices recommends that Interconnect slot 1 be reserved for SAS Storage Interconnect Module.
HPE Best Practices recommends that Interconnect slot 2 be used for secondary fabric Interconnect Modules.
HPE Best Practices recommends that Interconnect slot 3 be reserved for primary Ethernet or Ethernet w/FCoE fabric.
Interconnect slot 4 be reserved for redundant of Interconnect slot 1. Best practices recommends redundant SAS Interconnect Module.
Interconnect slot 5 be reserved for redundant of Interconnect slot 2. Best Practices recommends redundant secondary fabric Interconnect Modules.
Interconnect slot 6 be reserved for redundant of Interconnect slot 3. Best Practices recommends that this Interconnect be reserved for redundant primary Ethernet or Ethernet w/FCoE fabrics or links.
Max Load Input Power
The Total max effective Power Supply is validated with Total DC Power of the Server/Enclosure and not with Total AC Power(Max Load Input Power).
HPE Power Advisor
Supported Configuration
G2 PDU with C19 outlets paired with C20 to C13 power cord which support 12A or greater